medical X-ray machine
Your current location:Products > X-ray Accessories
YSX1628 X / Y ray Radiation Dosimeter Supplier

YSX1628 X / Y ray Radiation Dosimeter Supplier

High Performance YSX1628 X / Y ray Radiation Dosimeter, GM counting tube, measuring X-ray and γ-ray; Display screen: 4 numbers LCD. ...

  • High Performance YSX1628 X/Y ray Radiation Dosimeter


    The portable radioactive contamination dosimeter is a wearable device,which id produced with the functionally powerful MCU technology.

    It is mainly for testing x-ray and y-ray, and directly reading the dose and dose rate.

    In the scope of its measurement, the alarming threshold can be fixed or pre-set.When the threshold is overrun or block dose happens, the meter will send out light and sound alarm signals. As a wearable device, it features small size and low power.
    It is widely used in such fields as non-destructive flaw detection, nuclear power station,nuclear submarine, isotope application, and cobalt therapy in hospital.

    Features:
    1. High sensitivity, and response to environmental background.
    2. Measuring both dose and dose rate, and providing various alarming signals.
    3. Low power, small size, and easy use.

    Technical parameter:
    1. Detector:GM counting tube, measuring X-ray and γ-ray;
    2. Display screen: 4 numbers LCD;
    3. Measuring range:
        Accumulated dose equivalent: Hp(10)0.0usv~99.99msv;
        Dose equivalent rate: Hp (10)0.1usv/h~99.99msv/h;
    4. Response time: 3.6S-36S;
    5. Measuring rate response: <±20%(1usv/h~99.99msv/h)
    6. Energy response: <±30%(50KeV~1.3MeV)
    7. Relative inherent error: <±20%(137Cs).
    8. Alarm function and alarm valve value: Measuring rate and accumulated dose can preset alarm valve value in the measuring range. The fixed alarm valve value as follows:
        1).Accumulated dose: Per increase 0.1usv, a short noise and light each time: ≥50 usv, sound-light alarm5s,"ALARM"display.
        2.) Measuring rate: ≥25usv/h,sound-light alarm is about 6s,"ALARM" display.
        3. )Clogging alarm: when counting tube clogged, alarm continuously, "ALARM" display, alarm sound intensity is about 80 decibels at the 30 cm.
    9. The battery under voltage indicates: when Battery voltage <2.7 +/- 0.05 Vs, the instrument displays under voltage symbol "LOBAT". It still can work for more than 24 hours in the lower radiation place after under voltage symbol appears.
    10. Battery and consumption: AAA type 1.5 V alkaline battery(7#battery), consumption<2mw, continuous service: 720 hours.
    11. Temperature characteristic: < ±10%- 10degree -- +50degree.
    12. Temperature features: <±10% 95%RH(+35%);
    13. Size: 55(width)×92(length)×18(thickness).
    14. Weight: <75g,including battery <98g.


    YSX1628 X/Y ray Radiation Dosimeter

    High Performance YSX1628 X/Y ray Radiation Dosimeter

    High Performance YSX1628 X/Y ray Radiation Dosimeter
    Yuesen Med equipment purchase process

Inquiry

more>> Product Categories
Digital X-ray Machine
Floor-mounted Radiography
Mobile / Portable X-ray
C-arm X-ray Machine
Dental X-ray Machine
Mammography Machine
Veterinary X-ray Machine
Solutions
Solutions1
Service
Privacy Policy
Trade & Market
FAQ
Contact Us

Tel: +0086 20 34174605

Mob: +0086 18922329278

Fax: +0086 20 34174483

Email: wm001@ysenmed.com

Add: Room 201, 2nd Building, Haizhu Science & Technology Industrial Park (Shiji branch park), No.42 Huangpu Road, Xingang East, Haizhu District, Guangzhou 510330, PRC.