medical X-ray machine
Your current location:Products > Mammography Machine
High frequency mammography x-ray machine YSX0903

High frequency mammography x-ray machine YSX0903

High frequency mammography x-ray machine YSX0903, Generator Type: High Frequency Inverter 40kHz; C-ARM: Vertical Movement:60cm (70~130cm) Motorized; Tissue Compression: Manual and Motorized (Max 20kg) ...

  • High frequency mammography x-ray machine YSX0903 

    X-ray Generator 
    Generator Type: High Frequency Inverter 40kHz
    Input Power: Single phase 220VAC, 50/60Hz
    Radiographic Ratings: Large Focal Point 20-35KV/1-300mAs
                                        Small Focal Point 20-35KV/1-100mAs
    Power Rating:1.2kW

    X-ray Tube 
    Model: Fixed anode, China Hang Zhou XD7(X791)
    Focal Spot Size: Dual Focus 0.5mm
    Target Material: Molybdenum (Mo)
    Port Material: Beryllium (Be)
    Anode Heat Storage: 63KHU
    Anode Cooling: Air cooling
    Filtration: Mo(0.03mm),Al(0.5mm)

    Radiographic Stand
    C-ARM: Vertical Movement:60cm (70~130cm) Motorized
    Rotations Deg:±180° Motorized (Deg. Data Display)
    SID: 65cm

    Cassette Image Receptor
    18×24cm

    Line Voltage
    220Vac@15A, Single phase

    Comfortable Compression(Optional)
    When some degree of pressure is required for radiography, it allows you to presser the appropriate pressure(up to a maximum of 20kg)and is equipped with MICOM Control's Soft-touch system which is designed to minimize the discomfort of the examine with in the pressure range.
    Tissue Compression: Manual and Motorized (Max 20kg)
    Compression Force and Thickness Data Display
    Micom Control's Compression
    Automatic Release

    Intelligent Automatic Exposure Control (AEC) (Optional) 
    With the Automatic Exposure Control system, it is possible to produce images with reliable intensity suitable for and film, screen, or method of radiography.
    Furthermore, it greatly enhances the convenience of radiography by embedding the Full-AEC function which is capable of utilizing the Auto kV
    Type: Solid-State Detector or PMT Detector
    Microprocessor Control
    AEC Mode: Full AEC(Auto kV)
    Semi AEC (KV Select)
    Manual (kV, mAs Select)
    Density Adjustment: 10 density steps

    High frequency mammography x-ray machine YSX0903



    High frequency mammography x-ray machine YSX0903 control pannel
    High frequency mammography x-ray machine YSX0903 Control Pannel
    High frequency mammography x-ray machine YSX0903 Control Pannel
    High frequency mammography x-ray machine YSX0903 Control Pannel

     
    High Frequency Mammography X-ray Machine YSX0903
    High Frequency Mammography X-ray Machine YSX0903
    High Frequency Mammography X-ray Machine YSX0903
  • X-ray Generator 
    Generator Type: High Frequency Inverter 40kHz
    Input Power: Single phase 220VAC, 50/60Hz
    Radiographic Ratings: Large Focal Point 20-35KV/1-300mAs
                                        Small Focal Point 20-35KV/1-100mAs
    Power Rating:1.2kW

    X-ray Tube 
    Model: Fixed anode, China Hang Zhou XD7(X791)
    Focal Spot Size: Dual Focus 0.5mm
    Target Material: Molybdenum (Mo)
    Port Material: Beryllium (Be)
    Anode Heat Storage: 63KHU
    Anode Cooling: Air cooling
    Filtration: Mo(0.03mm),Al(0.5mm)

    Radiographic Stand
    C-ARM: Vertical Movement:60cm (70~130cm) Motorized
    Rotations Deg:±180° Motorized (Deg. Data Display)
    SID: 65cm

    Cassette Image Receptor
    18×24cm

    Line Voltage
    220Vac@15A, Single phase

Inquiry

more>> Product Categories
Digital X-ray Machine
Floor-mounted Radiography
Mobile / Portable X-ray
C-arm X-ray Machine
Dental X-ray Machine
Mammography Machine
Veterinary X-ray Machine
Solutions
Solutions1
Service
Privacy Policy
Trade & Market
FAQ
Contact Us

Tel: +0086 20 34174605

Mob: +0086 18922329278

Fax: +0086 20 34174483

Email: wm001@ysenmed.com

Add: Room 201, 2nd Building, Haizhu Science & Technology Industrial Park (Shiji branch park), No.42 Huangpu Road, Xingang East, Haizhu District, Guangzhou 510330, PRC.