Home > Products

500mA/125KV Single-phase Medical Diagnosis X Ray Machine YSX0227

500mA/125KV Single-phase Medical Diagnosis X Ray Machine YSX0227

Product Type:Conventional Diagnostic X-ray Machine

Place of origin:China

Model No:YSX0227

Price Terms:FOB/CIF/C&F

Payment Terms:L/C,T/T

Package:Plywood

Minimum Order:1 set

Delivery Time:7 days

Brand Name:YSENMED

500mA Medical Diagnosis X Ray Machine YSX0227

500mA Medical Diagnosis X Ray Machine YSX0227

Features :

1)Double table, double tube 500mA, 125kV, single-phase full-wave rectifier bridge.

2) The machine is equipped with X-ray tube capacity protection, rotating anode start protection, SCR-controlled radiographic timing diagram, the fluoroscopy load time cumulative device and the X-ray tube over-temperature protection devices, to ensure long-term safe operation of X-ray tube.

3) The fluoroscopy table has wide rotation range, table face movable, many film specifications, and easy to operate and equipped with a radiation and scattering of radiation sufficient protection to ensure the safety of operator and patients.

4) multi-function radiography table, with no ceiling-to-floor orbit, double rope protection against falling to protect pillar, beautiful in appearance, table’s vertical and horizontal movement can be flexible, the movement and rotation of X-ray tube assemblies flexible And lightly, electromagnetic brake, to holds the respective cassette.

5) With X-TV system and tomography device interface.

6) Suitable for small and medium sized hospitals in the X-ray fluoroscopy, spot film radiography, filter radiography, chest radiography purposes.

Part Name

Features and Parameters

High Voltage Generator

Power

Voltage

380V±10%

Frequency

50Hz±1Hz

Capacity

≥30KVA

Source resistance

≤0.3Ω

Fluoroscopy

Tube current

0.3-5mA continuously adjustable

Tube voltage

45-110KV continuously adjustable

Exposure time

≥3hours

Radiography

Tube current

30-500mA adjustable by steps

Tube voltage

45-125KV continuously adjustable

Exposure time

0.02-5S adjustable 23 steps

X-ray tube assemblies

X-ray tube models

XD51.20-40/125kV

Focus

Dual focus: 1×1  2×2

Anode limited speed

2800r/min

Heat capacity

140KHU

Collimator

radiography table used: Manual multi-leaf rectangular radiation field, continuous adjustment, illumination ≥ 100LX, 1min timing device

fluoroscopy table used: electric, rectangular radiation field

YSX1813 Radiography Table

Film specification

5"×7",8"×10",10"×12",11"×14",12"×15",

14"×14",14"×17"

Filter

Grid ratio: 10:1

Grid density: 40L/cm,

Convergence distance:100cm

Moving range: ≥ 610mm

Table movement

Vertical ± 560mm, horizontal± 100mm

Tube movement

Around the cross arm ± 180 °, around its longitudinal axis ± 90 ° vertical range ≥ 1100mm

Table height

700mm

Focusing distance

100cm

Table brake

Electromagnetic lock

Stand column movement

1500mm Around its own rotation ≥ ± 180 °, each 90 ° orientation, vertical travel 1500mm

YSX1815

Fluoroscopy Table

Table body movement

-15º--0º--+90º

Table surface movement

Longitudinal movement 700mm to head,electro-motion

Table surface height

820mm

Film devices

Vertical movement

600mm

Lateral movement

±100mm

Move back and forth

300 mm

Radiography Specifications

Full film 5 "× 7", 8 "× 10", 10 "× 12", 11 "× 14"

Half film 8 "× 10", 10 "× 12"

Quarter film 8 "× 10"

Lock method

Electromagnetic brake

Fixed grids

Grid ratio: 10:1

Grid density: 40L/cm

Convergence distance: 80cm

(Optional)YSX1807 vertical bucky stand

Lifting range

1450mm

Minimum distance from Radiography center to the ground

380mm

Radiography Specifications

8"×10"~14"×17"

Fixed grids

Convergence distance: 180cm,

Grid ratio: 10:1,

Grid density: 40L/cm

Standard Configuration Sheet

No.

Part Name

Qty.

1

Console

1(Piece)

2

High voltage generator component

1(Piece)

3

YSX1815 Diagnostic table

1(Piece)

4

125KV X Ray tube assemblies

2(Piece)

5

Manual collimator

1(Piece)

6

Electric collimator

1(Piece)

7

High voltage cable

2(Piece)

8

Multifunctional radiography table

1(Set)

9

Vertical Bucky Stand (optional)

1(Set)


Prev: High Voltage 400mA X-Ray Radiography Equipment YSX0226
Next: Mutifuntional 500mA High Voltage Medical Diagnosis X Ray Machine YSX0228
Recommended Products

50mA Conventional Diagnostic X-ray M

100mA/10KVA Medical X-Ray Equipm

100mA High Voltage Conventional X-r

High Voltage Single-phase Fluoroscop