Email: export@ysenmed.com
TEL: +86-020-34174486
MOB: +86-18928872752
Home > Veterinary Equipment > Veterinary X-ray Machine > Digital Portable Veterinary X-ray System With Flat Panel Detector YSX040-C VET

Digital Portable Veterinary X-ray System With Flat Panel Detector YSX040-C VET

100kV,4kW high frequency, Toshiba x-ray tube, portable& mobile, 16bit flat panel detector.
  • Model: YSX040-C VET
  • Brand:YSENMED
  • Price: Inquiry
  • Goods click count:1403
  • 销量:最近售出 14
  • Rank:: (已有0条评论)
  • gifts for buying:0 Integral
  • MOQ:1
  • Ship From:China Guangdong
  • Shipping: Within 5-8 working days.
Quantity: -+

Product details

Shipping methods

Payment methods

Digital Portable Veterinary X-ray System With Flat Panel Detector YSX040-C VET

Digital Portable Veterinary X-ray System With Flat Panel Detector YSX040-C VET

1. Composition

Main Components Parts Qty Remark
X-ray Units Portable high frequency x-ray unit 1 set  
Toshiba X-ray tube 1 set  
Collimator 1 pc  
DR System Digital detector 1 set  
Sync box 1 set  
laptop 1 set  
DR image processing software 1 set  
Auxiliaries Steel support 1 set Optional


2. Application

The 4kW portable digital high frequency x-ray unit is mainly suitable for extremities check, especially for rescues or diagnosis in field operation sites, battlefields, stadiums, vet clinics, etc.

 

3. Features

1)Toshiba x-ray tube

2) Simple & light structure;

3) 6-segment LED digital display;

4) Anatomical memories for 24 selection program;

5) Double-loop (analog & digital) high precision control mode;

6) High precision control in tube voltage & current;

7) Self-protection & auto-diagnosis available when malfunction occurs.

 

4. YSX040-C Specifications


  Model YSX040-C
Power supply Voltage: AC220V± 10%, 50/60Hz ± 1Hz
Capacity: ≥5kVA
Internal resistance: ≤0.5Ω
Maximum output power P =110kV×36mA=4kW
Nominal output power 100kV,40mA,0.1s,4kW
Frequency ≥40kHz
kV  adjustable range 40kV~110kV, continuous regulation, stepping 1kV
mA  adjustable range 36mA~60mA
mAs adjustable range 1mAs-190mAs,continuous regulation
Exposure time adjustable range 0.04s~3.2s
Toshiba X ray tube Focus: 1.6*1.6mm,
Thermal Capacity: 76kHU
Digital detector Limit resolution: 3.9LP/mm;
A/D convert:14bit;
Pixel region: 264×325mm;
Pixel matrix: 2080×2560;
Notebook Computer a) Model:Lenovo Y470N-IFI(H)
b) Processor: Intel Core i5-2410M(2.3GHz)
c) Memory capacity: 4GB
d) Hard disk: 750GB
e) Screen size: 14inch
Anatomical program 24 memory choices available
Accessories Standard: manual switch,cable
Optional: mobile steel support


Video of YSX040-C: http://youtu.be/tPXbI2K_6NU

Digital Portable Veterinary X-ray System With Flat Panel Detector YSX040-C VET
Digital Portable Veterinary X-ray System With Flat Panel Detector YSX040-C VET
Digital Portable Veterinary X-ray System With Flat Panel Detector YSX040-C VET

PC of vet digital x-ray system
Digital Portable Veterinary X-ray System With Flat Panel Detector YSX040-C VET
Software of the YSX040-C for Animal
Digital Portable Veterinary X-ray System With Flat Panel Detector YSX040-C VET


Test pictures for animal 
Digital Portable Veterinary X-ray System With Flat Panel Detector YSX040-C VET
Digital Portable Veterinary X-ray System With Flat Panel Detector YSX040-C VET
Digital Portable Veterinary X-ray System With Flat Panel Detector YSX040-C VET
Digital Portable Veterinary X-ray System With Flat Panel Detector YSX040-C VET
Digital Portable Veterinary X-ray System With Flat Panel Detector YSX040-C VET
Digital Portable Veterinary X-ray System With Flat Panel Detector YSX040-C VET

Previous: 20kW/200mA Veterinary Use High Frequency Xray Machine YSX200G VET
Next: 4.0kW Toshiba Tube Vet X-ray Machine With Table YSX040-B
Shipping methods
Payment methods
Get Price
Write down your demand below and we will contact you within 24h!
Your Name: *
Company Name: *
Address: *
Email: *
Phone: *
Contents: *
Code: captcha *
 
YSX040-C Digital Portable X-ray System to Congo Kinshasa
On May 2018, our sincere customers from Congo Kinshasa visited our company, our manager Kevin and colleague Iris had a meeting with them.
Time: 2018-05-18 14:38:30