Medical Respirator Equipment Mobile ICU Ventilator YSAV70B

10.4'' LCD Display Mobile Ventilator; Ventilation mode: A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH, SPONT; Tidal Volume:Setting Range: 50~1500ML Display Range: 0~2000ml ; resolution ratio: 10ml
  • Model: YSAV70B
  • Brand:YSENMED
  • Price: Inquiry
  • Goods click count:206
  • 销量:最近售出 25
  • Rank:: (已有0条评论)
  • gifts for buying:0 Integral
  • MOQ:1
  • Ship From:China Guangdong
  • Shipping: Within 5-15 days after payment
Quantity: -+

Product details

Shipping methods

Payment methods

Medical Respirator Equipment Mobile ICU Ventilator YSAV70B

Mobile ICU Ventilator




The YSAV70B ventilator is gas driven by medical compressed oxygen and compressed air. In the inspiratory phase, two streams of compressed gas (compressed oxygen and compressed air) flow into a high performance air-oxygen mixer to form a mix of oxygen and air with a certain pressure.

 

TECHNIQUES SPECIFICATIONS                                                   

Physical specifications

Display

10.4'' LCD Display

Mode:

pneumatically powered and electrically controlled system

Trolley:

Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions

Technical Specifications:                                                                                                                      

Gas requirement:

Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa

safety valve

<12.5 kPa

Respiratory Rate

1 ~ 99 bpm

Oxygen concentration output

21% ~ 100% adjustable

Maximum Minute ventilation

≥18L / min

modes of ventilation

A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH, SPONT

Ventilator compliance

≤30 Ml/kPa

PEEP:

0 ~ 1.0 kPa

Ptr:

-10 ~ 10 hPa

IMV frequency:

1~20 bpm

I/E Ratio:

4:1~1:4, Has the inverse ratio ventilation

Tidal Volume

Setting Range: 50~1500ML   Display Range: 0~2000ml ; resolution ratio: 10ml

Inspiratory Plateau:

0~1s

Maximum Safety Pressure

≤ 6.0kPa

Sigh:

one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point

Pressure limit range:

1.0~ 6.0kPa

Airway pressure alarm: Audible and visual and with yellow and red color indicating

Lower: 0.1 kPa ~ 6.0 kPa;   Upper: 0 ~ 5.0 kPa

±0.2 kPa

Ventilation Volume alarm:

≥ 18L/ MIN

Power Supply Alarm

Ac/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s

The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.

Operating conditions                                                                                                                            

Ambient temperature:

10 ~ 40oC

Relative humidity:

no higher than 80 %

Atmospheric pressure:

860 hPa ~ 1060 hPa

Power requirement:

100-120 Vac, 50/60 Hz;

Attention: the AC power supply used for the anesthesia machine must be well   grounded.

Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System.

Storage

Ambient temperature:

-15oC ~ +50oC

Relative humidity:

no higher than 95 %

Next: Medical ICU Ventilator Machine YSAV90B
Shipping methods
Payment methods
Get Price
Write down your demand below and we will contact you within 24h!
Your Name: *
Company Name: *
Address: *
Email: *
Phone: *
Contents: *
Code: captcha *
 
Ysenmed offer supper medical equipment for Myanmar new hospital, including operating room equipment, autoclave, hodpital furniture and so on
Time: 2018-04-11 13:28:58
20KW x ray machine and a large quantity hospital beds and other medical equipment to Ghana New Hospital
Time: 2017-08-03 14:40:52