Dual-Energy X-ray Bone Densitometer YSDXA-6

Model: YSDXA-6
YSDXA-6 Dual-Energy X‑ray Bone Densitometer delivers precise BMD analysis of lumbar spine, femur & forearm, full-body composition mapping, fast scans, QC software & DICOM support.
  • ModelDual-Energy X-ray Bone Densitometer YSDXA-6
  • BrandYSENMED
  • PriceGet Price
  • MOQ1
  • Ship FromGuangzhou, China
  • ShippingAny shipping terms convenient for customers
  • Description Get Price Review(0)

    I. Device Name: Dual-Energy X-ray Bone Densitometer

    II. Device Functions:
    Bone Mineral Density (BMD) Measurement: Lumbar spine, femur, forearm (T-score/Z-score analysis)
    Whole-Body Body Composition Analysis: Precise bone mass evaluation, prevention, and diagnosis
     
    III. Technical Parameters
    1. X-ray System
    1.1 Scanning Mode: Fan beam, continuous scanning
    1.2 Measurement Sites: Lumbar spine, femur, forearm
    1.3 Dual-Energy Generation: Dual-energy exposure (high/low kV switching)
    1.4 X-ray Tube Voltage Range: 70110 kV
    1.5 Maximum Output Power: 275 W
    1.6 Maximum Tube Current: 2.5 mA
    1.7 Tube Current Modes:
     
    Mode 1: 2.5 mA
     
    Mode 2: 1 mA
     
    Mode 3: 0.5 mA
    1.8 Cooling System: Oil + air cooling
     
    2. Detector
    2.1 Detector Type: Gadolinium Oxysulfide (GOS) scintillation detector
    2.2 Detector Channels: 16
    3. Scanning System
    3.1 Scan Bed Dimensions: Length 252 cm × Width 119 cm
    3.2 Patient Weight Capacity: 210 kg
    3.3 Maximum Scan Area: 202 cm × 60 cm
    3.4 Scan Time per Site:
     
    Lumbar spine: 21 sec
     
    Femur: 21 sec
     
    Forearm: 19 sec
    3.5 Positioning: Laser-guided positioning
     
    4. Calibration System
    4.1 Calibration Time: 20 min per cycle
    4.2 QC Software: Quality control test program + trend analysis
    4.3 Calibration Module: QA phantom calibration
    4.4 Repeatability: Coefficient of Variation (CV) 1%
    4.5 Accuracy Deviation: ≤±5%
    5. Software Package
    5.1 Operating Software: Full Chinese interface
    5.2 Multi-Site Integrated Reporting: Combines results from multiple sites into a single report
    5.3 Reporting Software: Generates image/data reports with editing capabilities
    5.4 Ethnic Databases: Chinese, Caucasian, African, Asian
    5.5 Automated Bone Edge Detection: Auto-ROI (Region of Interest) definition
    5.6 Real-Time Scan Adjustment: Fine-tune scan positioning via software
    5.7 Trend Analysis: Long-term BMD tracking
    5.8 DICOM 3.0 Support: Seamless PACS integration
    6. Clinical Functions
    6.1 Whole-Body Assessment & Body Composition Analysis:
     
    Color-coded body composition mapping
     
    Fat mass, lean tissue, muscle mass, fat percentage
    6.2 Lumbar Assessment: AP lumbar spine measurement
    6.3 Femur Assessment: Bilateral femur measurement
    6.4 Forearm Assessment: Forearm measurement
    6.5 Hip Analysis: Extended Gruen zonal analysis (19 zones)
    6.6 Metal Artifact Reduction: Eliminates interference from prostheses, implants, etc.
    6.7 One-Position Multi-Scan: Single positioning for lumbar spine + bilateral femurs
    6.8 Camera-Assisted Positioning: Enhances patient alignment accuracy
    6.9 Lateral Vertebral Assessment: BMD measurement and morphological analysis