We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.

Syringe & Infusion Pumps

Categories

Electric Syringe Infusion Pump YSZS-B50D

Model: YSZS-B50D
Compatible with syringes from (2/3ml), 5ml,10ml,20ml,30ml,50ml,60ml. Stackable to be the maximum 8 channels.
  • ModelYSZS-B50D
  • BrandYSENMED
  • PriceGet Price
  • MOQ1
  • Ship FromFrom Guangzhou, China
  • ShippingAny shipping terms convenient for customers
  • Share:
    Description Get Price Review(0)


    1.Compatible with syringes from (2/3ml), 5ml,10ml,20ml,30ml,50ml,60ml.

    2.Stackable to be the maximum 8 channels.

    3.High accuracy +/-2% after correct calibrated.

    4.Three work modes: Rate mode, Time mode and Weight mode.

    5.Bolus / Purge, KVO function.

    6.With drug libraries:17 categories of common drugs,1030 kinds of drug names in total.

    7.History recorded, real time displayed.

    8.12 hours continuous work after fully charged.

     

    Technical Specifications

    PARAMETER

    SPECIFICATION

    Applicable syringes

    2/3ml, 5ml,10ml,20ml,30ml,50ml,60ml of any standard

    Accuracy

    +/- 2% with correct calibration

    Rate mode

    50ml(60ml):0.1ml/h-1800.0ml/h (0.1ml/h step)
    20ml(30ml):0.1ml/h-800.0ml/h (0.1ml/h step)
    10ml:0.1ml/h-400.0ml/h (0.1ml/h step)

    5ml (2/3ml): 0.1~200ml/h (0.1ml/h step)

    (Programmable 0.01ml/h~9999.9ml/h)

    Time Mode

    SOL. VOL:0.1-999.9ml (0.1ml step)
    TIME:1-1999min (1min step)

    Body Weight Mode:

    Volume:0.1-999.9ml(0.1ml step)
    DRUG MASS:0.1-999.9mg 0.1mg step)
    DOSE:0.01-99.99ug/kg/min(0.01ug/kg/min step)
    WEIGHT:0.1-300kg(0.1kg the least step)

    Total Volume Range

    0.1-1999.9ml (0.1 ml step)

    Purge Rate

    50ml(60ml):1800.0ml/h,

    20ml(30ml):800.0ml/h,

    10ml:400.0ml/h, 5ml (2/3ml): 200ml/h

    Programmable and adjustable

    KVO Rate

    1ml/h

    Occlusion pressure

    Three level setting LOW, MEDIUM or HIGH

    Alarms

    Near empty, Syringe empty, Volume complete (when limit volume is set), Occlusion, Syringe loose, Operation error, Low battery, device failures.

    Three levels of alarm volume LOW, MEDIUM or HIGH

    Bolus Rate

    5ml: 10~200ml/h,10ml:10-300ml/h,20ml(30ml):10-600ml/h,

    50ml(60ml):10-1200ml/h

    Programmable and adjustable

    Bolus Volume

    Maximum of 25ml

    Interface

    RS-232  (Reserved port)

    Power source

    AC power supply: AC 100 to 240V( +/-10%),50/60Hz;
    Built-in Lithium Battery: Rechargeable, 11.1V, 2000mAh.

    12 hours of continuous operation

    Accessories:

    AC power line, Operational manual

    Protection Class

    Class I, Type CF,IPX4

    Dimension / Net weight

    230mm*150mm*125mm , 2.0kg

    Write down your demand below and we will contact you within 24h!
    ver_code
    Review

    ver_code
    1/3