Masimo Spo2 module
Performance Specifications
Dimension and Weight
-Dimension: 210mm*130mm*75mm
-Weight: 1kg(excluding accessories)
Power Supply
-Voltage: AC100~240V, 50/60HZ
-Adapter: Output 9VDC, 5A
Display
-7" color TFT LED
-Resolution: 800*480 pixels
Battery
-Type: Rechargeable lithium battery 7.4V/2200mAh
-Charge Cycle: ≥500 times
-Working time: 2-3 hours (optional larger battery for 4-5 hours)
Recorder (Option)
-Method: USB External Thermal printer
-Paper width: 50 mm (1.97 in)
-Printing speed: 12.5/ 25/ 50 mm/s
-Trace: Max. 3 tracks
-Recording way: Real-time Recording, Review Printing,
Periodic Recording, Alarm Recording
Alarm
-Level: Low, medium and high
-Indication: Auditory and visual
-Alarm volume adjustable
-Alarm pause time: 1min, 2min
-Parameter alarm type: Latch/ Unlatch
Input Device
-Touch screen (standard)
-Touch pen (standard)
System Output & Extensible Interface
-Ethernet Network: 1 standard RJ45 socket
-USB Port: 1
-Video Output: 1 HDMI port (option)
Operating Environment
-Temperature: 5 ~ 40 ℃
-Humidity: 15% ~ 80% (non-condensing)
-Atmosphere pressure: 86 KPa ~ 110 KPa
Transportation and Storage Environment
-Temperature: -20~50 ℃
-Humidity: 10%~90% (non-condensing)
-Atmosphere pressure: 86 KPa ~ 110 KPa
Safety
-IEC60601-1 Approved, CE marking according to MDD93/42/EEC
-With reference to RoHS Directive 2011/65/EU recasting
Trend & Reviewing
-Trend: 2160 hours
-ARR events: 128 groups of ARR events and associated waveform
-NIBP measurement reviewing: 2000 groups
-Waveform review: 2 hours
-Alarm event: 2000 groups of parameter alarms events and associated parameter
ECG
-Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
-Protection: Breakdown Voltage 4000VAC 50/60Hz; Defibrillator proof
-Gain: 2.5mm/mV (×0.25), 5.0mm/mV (×0.5), 10mm/mV (×1), 20mm/mV (×2), 40 mm/ mV (×4), Auto
-Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
-ECG signal range: ±12 mV (Gain × 0.25)
-Accuracy: ±1bpm/ ±1%, whichever is greater
-Resolution: 1 bpm
-Leakage Current < 10 μA
-Baseline Recovery:
≤ 3s after defibrillation (Monitor mode)
≤ 1s after defibrillation (Surgery mode)
-Bandwidth: Surgery 1 ~ 25 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 120 Hz
-Indication of Electrode Separation: Every electrode (exclusive of RL)
Heart Rate
-Measure range:
Adult: 0bpm; 10 ~ 300 bpm
Neo/Ped: 0bpm; 10 ~ 350 bpm
-Resolution: 1 bpm
-Accuracy: ± 1% or ± 1bpm, whichever is greater
ST Measurement
-Range: -2.0 ~ +2.0 mV
-Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is greater
-Other range: unspecified
-Resolution: 0.01mV
Respiration
-Method: Impedance between RA-LL, RA-LA
-Gain: ×0.25, ×0.50, ×1, ×2, ×4
-Respiration Rate: 0bpm, 6 ~ 150 BrPM
-Sweep speed: 6.25 mm/s, 12.5 mm/s, 25mm/s
-Resolution: 1 BrPM
-Accuracy: ±2 bpm or ±2%, whichever is greater
-Apnea Alarm: 10 ~ 60 s
Temperature
-Technique: Thermistor probe (2.25K)
-Channel: Single-channel
-Measuring and Alarm
Range: 0.0 ℃~ 50 ℃ (32℉~ 122℉)
-Unit: Celsius (℃), Fahrenheit ( ℉)
-Resolution: 0.1℃or 1℉
-Accuracy: ±0.1℃(exclusive probe)
NIBP
-Method: Oscillometric
-Measure mode: Manual, Auto, STAT
-Measure Interval in AUTO Mode 1~480 min
-STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
-Measure and Alarm Range:
Adult: SYS: 30 ~ 270 mmHg
DIA: 10 ~ 220 mmHg
MEAN: 20 ~ 235 mmHg
Pediatric: SYS: 40 ~ 235 mmHg
DIA: 10 ~ 220 mmHg
MEAN: 20 ~ 225 mmHg
Neonate: SYS: 30 ~ 135 mmHg
DIA: 10 ~ 110 mmHg
MEAN: 20 ~ 125 mmHg
-Static pressure accuracy: ±3mmHg
-Resolution: 1mmHg
-Accuracy: Maximum Mean error ±5mmHg
Maximum Standard deviation ≤8mmHg
-Over pressure Protection: Dual protection via software & hardware
Performance Specifications
Suntech NIBP
-Measure Method: Oscillometric. Diastolic values correspond to Phase 5 Korotkoff sound
-Measure Range:
Adult: SYS: 40 ~ 260 mmHg
DIA: 20 ~ 220 mmHg
MEAN: 26 ~ 220 mmHg
Pediatric: SYS: 40 ~ 230 mmHg
DIA: 20~ 160 mmHg
MEAN: 26 ~ 183 mmHg
Neonate: SYS: 40 ~ 130 mmHg
DIA: 20 ~ 100 mmHg
MEAN: 26 ~ 110 mmHg
-PR Range: 30 to 220 BPM
-PR Accuracy: ±2% or ±3 BPM, whichever is greater
-Pressure Transducer Accuracy: ±3mmHg between 0 mmHg and 300 mmHg
for operating conditions between 0℃ and 50℃
-Deflate Rate: Deflation step size varies with heart rate, cuff pressure and cuff volume
-Initial Inflation Pressure:
ADULT: 160 mmHg (default)
Variable from 120 to 280 mmHg
PEDIATRIC: 140 mmHg (default)
Variable from 80 to 280 mmHg
NEONATE: 90 mmHg (default)
Variable from 60 to 140 mmHg
SpO2 (Digital Technic)
-Measurement Range: 0 ~ 100 %
-Resolution: 1 %
-Accuracy: ±2% (70% ~ 100%)
±3 % (35% ~ 69%)
Unspecified (0 ~ 34%)
-Support Pitch tone and multi-level volume
Pulse Rate
-Measuring and Alarm Range: 25~250bpm
-Accuracy: ±1% or ±1 bpm, whichever is greater
-Resolution: 1bpm
Nellcor-SpO2 (Option)
-Measurement Range: 0 ~ 100 %
-Resolution: 1 %
-Accuracy: 70% ~ 100%, ±2 %