| 1: | Summary of main specifications and system |
| 1.1 | Portable type full digital color Doppler ultrasound main unit |
| 1.2 | Ultrasonic host operating system: Windows operating system |
| 1.3 | Applications: Abdomen, obstetrics, gynecology, heart, urinary system, small organs, superficial, blood vessels, pediatrics, newborns, musculoskeletal |
| 1.4 | Probes: Convex probe, Tran-vaginal probe, Linear probe, Micro-convex probe, Cardiac probe,4D Volume probe |
| 1.5 | Applications and report: Abdominal,OB,GYN,Cardiac,Urinary,Small Parts,Superficial, Vascular, Pediatrics, Advanced measurement software packages, report software packages, case management software packages, etc. |
| ☆1.6 | carotid artery intima measurement thickness(IMT) |
| ☆1.7 | Automatic spectral envelope measurement |
| 1.8 | Full digital transmission and reception of beam synthesizer |
| 1.9 | Color Doppler imaging(C) |
| 1.10 | Pulse Doppler Imaging(PW) |
| 1.12 | Continuous wave Doppler imaging(CW) |
| ☆1.13 | B/C/D Real-time three synchronous imaging |
| ☆1.14 | Power Doppler imaging(PDI) |
| ☆1.15 | Direct power Doppler imaging(DPDI) |
| 1.16 | M mode imaging |
| ☆1.17 | Anatomic M mode imaging |
| ☆1.18 | Color Doppler M mode imaging |
| ☆1.20 | Tissue Doppler imaging(TDI) |
| ☆1.21 | Strain rate imaging (SRI) |
| 1.22 | Tissue harmonic imaging(THI) |
| 1.23 | Fusion harmonic imaging(FHI) |
| 1.24 | Speckle Reduce imaging(SRI) |
| ☆1.26 | Deflection imaging |
| ☆1.27 | Trapezoidal imaging |
| 1.28 | Adaptive velocity optimization |
| ☆1.29 | Free hand 3D |
| 1.30 | Real time 3D imaging(3D/4D) |
| 1.31 | DICOM3.0 |
| 1.32 | Monitor:15 inch,high definition ultrasonic display |
| 1.34 | Physical clipboard: save the image on the left side of the screen, which can be directly saved or deleted. |
| 1.35 | The system has the function of on-the-spot upgrade |
| 1.36 | Presupposition: for different inspection of the viscera, preset the inspection conditions for the best image, reduce the adjustment of the operation, and the commonly used external adjustment and combination regulation. |
| 1.37 | Probe interface: 3 active |
| 1.38 | 10 kinds of system language |
| 1.39 | Depth:≥360mm; |
| 1.40 | Extended imaging |
| 2: | Probes |
| 2.1 Convex probe | Fundamental Frequency:2.0MHz/2.3MHz/2.5MHz/3.0MHz/3.5MHz/4.0MHz/4.6MHz/5.0MHz/5.4MHz, Harmonic Frequency: 4.0MHz/4.6MHz/5.0MHz, |
| 2.2 Linear probe |
Fundamental Frequency:4.0MHz/4.6MHz/5.0MHz/6.0MHz/7.0MHz/8.0MHz/9.2MHz/10.0MHz/12.0MHz/13.3MHz, Harmonic Frequency: 8.0MHz/9.2MHz/10.0MHz, |
| 2.3 Trans-vaginal probe | Fundamental Frequency: 3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz/10.0MHz, Harmonic Frequency: 6.0MHz/7.0MHz/8.0MHz, |
| 2.4 Micro-convex probe | Fundamental Frequency: 3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz, Harmonic Frequency: 6.0MHz/7.0MHz/8.0MHz, |
| 2.5 Cardiac probe | Fundamental Frequency:1.7MHz/1.9MHz/2.1MHz/2.5MHz/3.0MHz/3.4MHz/3.8MHz/4.2MHz/5.0MHz, Harmonic Frequency: 3.4MHz/3.8MHz/4.2MHz, |
| 2.6 4D Volume probe |
Fundamental Frequency: 2.0MHz/2.5MHz/3.0MHz/3.3MHz/3.7MHz/4.0MHz/5.0MHz/6.0MHz, Harmonic Frequency: 4.0MHz/5.0MHz/6.0MHz, |
| 3: | 2D imaging mode |
| 3.1 | Gain:0-100,Step 2 adjustable |
| 3.2 | TGC:8 segment adjustable |
| 3.3 | Maximum focus point:≥7, which can be moved throughout the whole process. |
| 3.4 | Speckle reduction:0-5,5 level |
| 3.5 | Space Synthesis:0-2,2 level(Liner probe: 3 level, cardiac probe:0) |
| 3.6 | Dynamic:30-180,35 level,step 5 adjustable |
| 3.7 | Line density:low、middle、high,3 level |
| 3.8 | Frame correlation:0-4,4 level |
| 3.9 | Noise reduction:0-5,5 level |
| 3.10 | Edge Enhancement:0-5,5 level |
| 3.11 | Sound power:2-10, 9 level |
| 3.12 | Grey scale:0-67, 67 level |
| 3.13 | False color:0-67,67 level |
| 3.14 | Image style:Soft-Comparison,2 level |
| The screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, gray scale and other 11 parameters can be adjusted | |
| 4: | Color Doppler imaging mode |
| 4.1 | Blood gain:0-100,Step 2 |
| 4.2 | Parameter display:Velocity、Variance |
| 4.3 | B-Restrain(B/W restrain):0-7, 7 level |
| 4.4 | Speed Through:0-8, 8 level |
| 4.5 | Sampling number:6-24, 7 level |
| 4.6 | Blood flow preferred:0-8, 8 level |
| 4.7 | Filtering:1-6, 6 level |
| 4.8 | Sound power:2-6, 4 level |
| 4.9 | Noise reduction:0-4, 4 level |
| 4.10 | Smooth treatment:0-4, 4 level |
| 4.11 | Frame correlation:0-6, 6 level |
| 4.12 | Chromatography(Blood flow graph):0-37, 37 level |
| 4.13 | Line density:Low-Middle-High, 3 level |
| 4.14 | Frequency:4 level adjustable |
| 4.15 | Velocity:Minimum 0.4K,Maximum 40.5K Convex probe:0.4K-4.3K-38.5K Linear probe:0.4K-14.7K-39.0K Trans-vaginal probe:0.4K-7.8K-39.7K Volume probe:0.4K-4.2K-34.8K Micro-convex probe:0.4K-10.3K-40.5K cardiac probe:0.4K-7.8K-39.7K |
| PS:The frequency of the probe changes and the frequency value changes | |
| PS:Frame rate changes with speed | |
| 5: | Pulse wave Doppler(PW) |